For 11kV distribution networks, Qiangchi supplies project-configured RMU and switchgear solutions selected from the QCL-12 product family. The equipment class, insulation scheme, protection concept and panel arrangement are confirmed against the project single-line diagram and local utility requirements.
Product overview
Recommended family: QCL-12
Selection basis: 12kV equipment class
Qiangchi supports single-line review, functional-unit selection, interlocking logic, cable-interface coordination, secondary schematic review, routine inspection and export documentation. The final supply scope is governed by the signed technical agreement.

Technical selection parameters
| System / equipment class | 12kV equipment class |
|---|---|
| Rated current | Selected according to feeder duty and project specification |
| Short-circuit duty | Confirmed from the project fault-level study and specification |
| Functional units | Incoming, outgoing, bus section, metering, protection and transformer feeder as required |
| Protection & control | Relay, CT/VT, indication, motor operation and communication options configured per project |
| Cable interface | Termination type, cable size, entry direction and compartment arrangement confirmed before production |
| Environment | Indoor/outdoor enclosure, altitude, temperature, humidity, pollution and seismic conditions must be stated |
| Applicable standard | IEC or specified local/utility standard, subject to technical confirmation |
Typical applications
Utility secondary distribution, industrial plants, renewable-energy collection systems, commercial infrastructure, mining, transportation facilities and prefabricated substations.
Information required for quotation
Please provide the single-line diagram, system voltage and frequency, rated current, fault level and duration, feeder functions, cable details, protection requirements, installation conditions, applicable standards, quantity and delivery destination.
Engineering review and quotation
Download the available product-family document, then send the project data for configuration confirmation. Published information is for preliminary selection and does not replace the signed technical agreement.
Download technical documentRequest a quotationWhatsApp engineering
Buyer Decision Support
Recommended Product
QCL-12 gas-insulated RMU or XGN15-12 air-insulated RMU
11 kV networks commonly use equipment with a 12 kV rated-voltage class. Final insulation level follows the applicable standard and project specification.
Engineering Inputs
Send voltage, current, fault level, frequency, SLD, functional units, protection scheme, cable data and service conditions.
Project Deliverables
Configuration review, datasheet, GA drawing, technical clarification, inspection/FAT coordination and export documentation.
Frequently Asked Questions
Is this page a final equipment specification?
No. It is a voltage-based selection entry. Final ratings, dimensions, components and interfaces are confirmed in the approved technical agreement and drawings.
Can Qiangchi review an EPC single-line diagram?
Yes. Send the SLD, BOQ and specification for functional-unit selection and a project-specific proposal.
Can drawings and FAT documents be supplied?
GA drawings, technical submittals and agreed inspection or FAT records can be coordinated for confirmed orders.
Use the Product Selector 路 Compare Switchgear Types 路 Request Technical Proposal
Confirm the Correct Voltage-Class Equipment
System voltage alone does not complete product selection. Confirm rated voltage, insulation level, rated current, short-circuit current and duration, frequency, functional units, cable arrangement, application and required standard before quotation.
View QCL-12 RMU 路 Selection Guides 路 Technical Downloads 路 Request a Quote 路 WhatsApp Engineering Team