QCL-12 12 kV gas-insulated ring main unit switchgear

Medium Voltage Switchgear Product Comparison

Engineering Selection Guide

Medium Voltage Switchgear Product Comparison

Compare insulation technology, voltage range, current capacity, footprint and project fit before requesting a technical proposal. Final selection should follow the project SLD, protection philosophy and local utility requirements.

Quick Product Family Comparison

Product familyTypical voltage coverageRated currentBest suited for
QCL-12 / QCL-24 GISUp to 12 / 24 kV630 / 1250 ACompact substations, utilities, industrial and renewable projects
QCL-40.5 GIS40.5 kV class630 / 1250 / 2500 / 3150 AHigher-voltage distribution, utilities and large industrial systems
Environmental Gas RMUUp to 24 kV630 / 1250 ASF₆-reduction projects and compact distribution networks
QCG-12 Solid-Insulated RMUUp to 24 kV630 / 1250 ACompact, sealed and environmentally focused applications
XGN15-12 Metal-Enclosed Switchgear12 kV classProject dependentSecondary distribution and indoor substations
QCDL Vacuum Circuit BreakerMedium-voltage rangeConfiguration dependentProtection and switching in MV panels
FLN36 SF6 Load Break SwitchMedium-voltage rangeConfiguration dependentRMU and distribution switching applications

QCL-40.5 breaking-current options: 20 / 25 / 31.5 kA. Ratings and panel configurations must be confirmed against the final system design.

AIS vs GIS vs Solid-Insulated

Decision factorAISGIS / gas-insulatedSolid-insulated
FootprintGenerally largerCompactCompact
Environmental isolationMore exposed to ambient conditionsPrimary circuit sealed in gas tankPrimary circuit encapsulated in solid insulation
Maintenance approachAccessible componentsReduced primary-circuit exposureReduced gas-management requirements
Project fitConventional substations with available spaceSpace-limited, harsh-environment and prefab projectsProjects prioritizing sealed insulation and SF₆ reduction

Choose by Project Priority

Minimum Footprint

Start with QCL GIS, environmental gas RMU or QCG solid-insulated RMU. Confirm cable access and future extension needs.

High Current at 40.5 kV

Evaluate QCL-40.5 with current coverage through 3150 A and breaking-current options up to 31.5 kA.

Panel Integration

Evaluate QCDL vacuum circuit breakers and FLN36 load break switches according to the panel scheme and mechanism requirements.

Information Required for an Accurate Comparison

System

Rated voltage, frequency, neutral earthing method and short-circuit level.

Configuration

SLD, feeder quantity, incomer/bus coupler arrangement and protection requirements.

Site

Indoor/outdoor location, altitude, ambient temperature, humidity and applicable standards.

Need a Side-by-Side Technical Proposal?

Send the SLD and project specification. We will shortlist suitable product families and identify the points that need engineering confirmation.

Request Product ComparisonUse Product Selector