QCL-12 12 kV gas-insulated ring main unit switchgear

QCL-12 / Medium-voltage distribution

12 kV SF6 ring main unit

A compact, modular SF6-insulated RMU for utility distribution, secondary substations and industrial networks. Select the C, F, V and supporting functions around your project scheme.

12 kVRated voltage
50 HzRated frequency
SF6Insulation system

Your SLD, system ratings and installation requirements define the final configuration.

12kV Gas-Insulated Ring Main Unit
QCL-12 configuration reference. Final appearance and arrangement follow the approved project drawings.

Designed around the application

From network requirements to a clear equipment specification

Discuss feeder functions, protection, cable interfaces and installation conditions together, before fixing the supplied arrangement.

01

Secondary distribution

For ring-network feeders and secondary substations, with functional units selected to suit the distribution scheme.

02

Industrial & building projects

Match the equipment to load requirements, protection coordination, the installation environment and project specification.

03

EPC & panel integration

Coordinate the single-line diagram, general arrangement, auxiliary supply and technical documents before supply.

Technical reference

Key specifications, with their scope made clear

These values describe the documented product-family range. Confirm the selected functional unit and project requirements before ordering.

QCL-12 technical reference values
ItemProduct-family value
Rated voltage12 kV
Rated frequency50 Hz
Insulation systemSF6 gas insulation
C load-switch rated current630 A
F fuse-combination circuit125 A fuse circuit; fuse selection is project-specific
V vacuum-switch rated current630 A
Power-frequency withstand voltage42 kV; 48 kV across the isolating distance
Lightning impulse withstand voltage75 kV; 85 kV across the isolating distance
Functional arrangementC / F / V and project-configured cable, bus or metering functions
Dimensions and interfacesConfirm against the selected arrangement and approved drawings

Final supply is governed by the approved technical agreement, drawings and order documents. Product-family ratings are not a substitute for the applicable test reports.

Functional units

Build the line-up from your single-line diagram

Start with the feeder function. Confirm switching duty, protection, earthing, interlocks and interfaces for the complete arrangement.

C

Load-break switch

Ring-network switching function. Confirm the operating mechanism, earthing arrangement and required interfaces.

F

Switch-fuse combination

Transformer protection using a selected fuse arrangement. Fuse selection follows the transformer and coordination requirements.

V

Vacuum circuit-breaker

Feeder or transformer protection. Confirm the protection relay, instrument transformers and auxiliary supply.

Additional project functions

Discuss cable connection, bus sectionalising, voltage-transformer or metering functions as required by the scheme. Dimensions, termination positions, operating clearances and extension interfaces need the selected arrangement drawing.

Explore drawings & interfaces

Engineering documents

The right document for the decision in front of you

Check the model, revision and configuration scope before using a document in a project specification.

01 / Product information

Catalogues & data sheets

Review the product-family overview and technical reference values for QCL-12.

Download QCL-12 catalogue (PDF)

02 / Project coordination

Drawings & interfaces

Discuss the selected line-up, installation envelope and cable connection requirements.

Explore drawing support

Need a document for a specific unit or project? Include that requirement in your enquiry. Catalogue pages and reference drawings are distinct from approved project documents.

Make your enquiry easier

A short question is enough to start

If you have a specification, send it with your enquiry. If you do not, tell us your country, the equipment you need and what it will supply.

  • Project country and installation conditions
  • Rated voltage and frequency
  • SLD, feeder functions and quantity
  • Load current and short-circuit requirements
  • Cable details and auxiliary supply
  • Required documents and delivery schedule

QCL-12 questions

Can QCL-12 be used for an 11kV network?

QCL-12 is a 12kV-class product. Suitability for a 10kV or 11kV system depends on the insulation requirements and project specification.

Which functional units are available?

C cable-switch, F switch-fuse, V circuit-breaker, PT and metering functions can be arranged to match the approved SLD.

What does 630A / 25kA mean?

630A describes the normal-current rating; 25kA describes short-circuit withstand duty. The required duration and ratings must be checked for the selected functional unit.

What information is needed for a quotation?

Start with your country, equipment type and approximate quantity if known. For a firm technical offer we will confirm the voltage, current, fault level, functional units, cable interfaces, protection and delivery requirements.

Which type-test documents can I review?

Model-specific report references are 2026XHT06258, 2026XHT06259 and 2026XHT06260 for the stated C, F and V units. Each report applies only to its tested model and scope.

Can I request GA drawings and FAT?

Project-specific GA drawings follow configuration clarification. The inspection and FAT scope, including applicable mechanical, interlocking and electrical checks, is agreed for the order.

Discuss your QCL-12 requirement

Bring the project. Let us help define the equipment.

Share your requirements with Qiangchi. We will help you clarify the configuration and the documents needed for quotation.