XGN15-12 Air-Insulated Ring Main Unit
12 kV-class air-insulated switchgear for 11/12 kV distribution systems.
Request Technical ProposalSend Your SLDWhatsApp EngineerProduct Overview
XGN15-12 is the 12 kV-class air-insulated RMU/switchgear family. It can be selected for 11 kV systems within the 12 kV equipment class. Other project voltage classes—including 17.5, 24, 33, 35, 36 and 40.5 kV—are supplied through the appropriate product families and project-specific configurations.

Customer Benefits
Compact Project Integration
Configuration focused on installation and system needs.
Engineering Coordination
SLD, GA and technical submittal support.
Flexible Configuration
Functional units selected for project scope.
Factory Testing
Inspection and FAT support before shipment.
Technical Parameters
| Item | Value |
|---|---|
| Series | XGN15-12 |
| Rated Voltage | 12 kV equipment class (including 11 kV systems) |
| Rated Current | 630 A |
| Frequency | 50/60 Hz |
| Short-Time Withstand Current | Project-specific; confirm against the controlled datasheet and approved SLD |
| Configuration | Load-break switch, fused switch, VCB, metering and PT panels |
Values shown are standard selectable ratings. Final configuration follows the approved SLD, controlled datasheet and project technical agreement.
Functional Units and Configuration
CVFPTM Availability depends on the confirmed product series and SLD.
Applications
Utility Distribution
Project-specific selection and engineering review.
EPC & Substation
Project-specific selection and engineering review.
Industrial Power
Project-specific selection and engineering review.
Solar & BESS
Project-specific selection and engineering review.
Infrastructure
Project-specific selection and engineering review.
Mining
Project-specific selection and engineering review.
Product Details
The modular lineup supports incoming, outgoing, transformer-protection, circuit-breaker, metering and PT functions. Panel quantity, operating mechanism, interlocking, cable termination and secondary-control requirements are coordinated against the approved SLD and project specification.
GA Drawing and Dimensions
Overall dimensions and panel arrangement depend on the selected functional units. Send the SLD, cable-entry direction and available installation space to receive a project-specific GA drawing.
Typical SLD
Common schemes include ring incoming/outgoing feeders, fused transformer protection, VCB protection, metering and PT panels. The final single-line diagram is prepared against the confirmed protection philosophy and utility requirements.
Manufacturing and Quality
Assembly, busbar, secondary wiring, inspection, electrical testing and FAT evidence.
Engineering Documents
Technical Datasheet
Rating schedule and configuration sheet prepared for the selected lineup.
GA & SLD
Project-specific arrangement and single-line diagram after requirement review.
Quality Documents
Inspection, routine-test and FAT documentation available for confirmed orders.
FAQ
What is the XGN15-12?
It is a 12kV-class air-insulated ring main unit used for switching, protection and distribution in 11/12kV networks.
Can XGN15-12 be used on an 11kV system?
Yes. An 11kV network commonly uses equipment from the 12kV rated-voltage class, subject to the project insulation level and utility specification.
Which functional units are available?
Typical arrangements include load-break switch, fuse-switch, circuit-breaker, metering and PT units. Final availability follows the approved SLD.
What does 630A mean?
630A is the normal-current rating for the main circuit. Cable, busbar and feeder selection must also satisfy the project load and temperature-rise requirements.
What information is required?
Voltage, current, fault level, frequency, quantity, SLD, BOQ, cable details and technical specification.
Are dimensions fixed?
Panel dimensions and lineup length depend on the functional units, mechanism, cable entry and auxiliary equipment. Final dimensions are issued in the approved GA drawing.
Can FAT be arranged?
Yes. Routine tests, witness points and project document requirements can be agreed before production.
Can Qiangchi support OEM or EPC projects?
Yes. Project-specific configuration, drawings, component coordination and technical submittal support are available against confirmed requirements.
Have an MV Project?
Send us your voltage, quantity, SLD or technical specification.
Request Technical ProposalSend Your SLDWhatsApp EngineerModel Meaning
XGN15 identifies a metal-enclosed air-insulated ring-main-unit family; 12 identifies the 12kV equipment class. Functional configuration and installed switching devices are confirmed from the project SLD and specification.
XGN15-12 is an air-insulated product route for 10kV and 11kV distribution projects. It must not be confused with the QCL gas-insulated product family.
Service Conditions & Project Confirmation
| Ambient temperature | Subject to project specification and technical confirmation |
|---|---|
| Altitude | State the installation altitude in the RFQ; derating or design review may be required |
| Relative humidity | Confirm maximum and average project conditions |
| Pollution and corrosion | State pollution level, salt mist, dust and corrosive atmosphere where applicable |
| Seismic condition | Project-specific requirement to be confirmed |
| Installation | Indoor or outdoor enclosure, cable entry, room dimensions and service aisle must be specified |
Standards and Technical Compliance
The applicable IEC standards, utility requirements, project specifications, inspection plan and document list are confirmed during technical clarification. Compliance statements apply only to the final approved configuration; no unverified certificate or test claim is implied.
Engineering, Packing & Shipment
After drawing approval, Qiangchi coordinates production, inspection, routine testing and the agreed FAT scope. Finished equipment is protected for handling and export shipment according to cabinet size, destination, transport method and contractual packing requirements.
Related Technical Guides
Review the Product Finder, Product Comparison and Selection Guides.
Request Project Configuration
Send the SLD, BOQ, specification, voltage, current, fault level, quantity and destination.
Reviewed by Qiangchi Engineering Team · Updated September 12, 2026
Engineering Answers for XGN15-12 Air-Insulated Ring Main Unit
What is this product?
XGN15-12 Air-Insulated Ring Main Unit is a Qiangchi medium-voltage product configured for project-specific distribution requirements.
Which voltage levels are available?
12 kV class for 10/11/12 kV distribution projects subject to the approved specification.
Where is it used?
It is used in air-insulated ring-main and distribution switchgear applications.
How to select the configuration?
Selection follows the system voltage, rated current, short-circuit level, functional units, protection concept, cable interface, installation conditions and approved SLD.
Which standards and tests apply?
Applicable standards, routine tests and FAT scope follow the approved configuration and technical documents.
What information is required for quotation?
Send the SLD, system voltage, frequency, rated current, short-circuit level, quantity, project stage, required documents and delivery requirements.