40.5kV GIS

40.5kV Gas-Insulated Switchgear

QCL-40.5 is Qiangchi鈥檚 compact gas-insulated switchgear platform for 40.5kV-class applications. Available rated-current configurations include 630 / 1250 / 2500 / 3150 A; all remaining electrical ratings and the final panel configuration are confirmed against the project specification and approved drawings.

Product overview

Recommended family: QCL-40.5

Selection basis: 40.5kV equipment class

Qiangchi supports single-line review, functional-unit selection, interlocking logic, cable-interface coordination, secondary schematic review, routine inspection and export documentation. The final supply scope is governed by the signed technical agreement.

40.5kV Gas-Insulated Switchgear product family reference image
Product-family reference image. Final appearance and configuration vary by project.

Technical selection parameters

System / equipment class40.5kV equipment class
Rated current630 / 1250 / 2500 / 3150 A (available by confirmed QCL-40.5 configuration)
Short-circuit dutyConfirmed from the project fault-level study and specification
Functional unitsIncoming, outgoing, bus section, metering, protection and transformer feeder as required
Protection & controlRelay, CT/VT, indication, motor operation and communication options configured per project
Cable interfaceTermination type, cable size, entry direction and compartment arrangement confirmed before production
EnvironmentIndoor/outdoor enclosure, altitude, temperature, humidity, pollution and seismic conditions must be stated
Applicable standardIEC or specified local/utility standard, subject to technical confirmation

Typical applications

Utility secondary distribution, industrial plants, renewable-energy collection systems, commercial infrastructure, mining, transportation facilities and prefabricated substations.

Information required for quotation

Please provide the single-line diagram, system voltage and frequency, rated current, fault level and duration, feeder functions, cable details, protection requirements, installation conditions, applicable standards, quantity and delivery destination.

Engineering review and quotation

Download the available product-family document, then send the project data for configuration confirmation. Published information is for preliminary selection and does not replace the signed technical agreement.

Download technical documentRequest a quotationWhatsApp engineering

Buyer Decision Support

Recommended Product

QCL-40.5 gas-insulated switchgear

Available rated-current configurations include 630/1250/2500/3150 A; final duty follows the approved project design.

Engineering Inputs

Send voltage, current, fault level, frequency, SLD, functional units, protection scheme, cable data and service conditions.

Project Deliverables

Configuration review, datasheet, GA drawing, technical clarification, FAT coordination and export documentation.

Frequently Asked Questions

Is this a final specification?

No. Final ratings, dimensions and interfaces follow the approved technical agreement and drawings.

Can Qiangchi review an EPC SLD?

Yes. Send the SLD, BOQ and specification for a project-specific proposal.

Can drawings and FAT documents be supplied?

GA drawings, technical submittals and agreed inspection records can be coordinated for confirmed orders.

Product SelectorProduct ComparisonRequest Technical Proposal

Confirm the Correct Voltage-Class Equipment

System voltage alone does not complete product selection. Confirm rated voltage, insulation level, rated current, short-circuit current and duration, frequency, functional units, cable arrangement, application and required standard before quotation.

View 33/35/36/40.5kV GISSelection GuidesTechnical DownloadsRequest a QuoteWhatsApp Engineering Team