QCL-24 24 kV gas-insulated switchgear front view

QCL-24 Gas-Insulated Switchgear

QCL-24 SERIES
24kV Gas-Insulated Ring Main Unit

Project-configured SF6 gas-insulated switchgear for 20/22/24kV utility distribution, EPC substations, industrial networks, solar plants, BESS and infrastructure.

24 kVRated Voltage
630 ARated Current
20/25 kA, 3 sShort-Time Withstand
50 HzFrequency
Request Technical ProposalSend Your SLDWhatsApp Engineer

Product Overview

QCL-24 is designed for switching, protection, measurement and distribution in 24kV-class systems. The sealed primary system and modular functional units support compact substations and project-specific feeder arrangements. Final configuration is based on the approved SLD and specification.

Core Advantages

Compact Footprint

Suitable for space-limited substations and distribution rooms.

Flexible Feeder Design

Incoming, outgoing, protection, metering and PT functions are coordinated to the SLD.

Reliable Operation

Sealed primary circuit, mechanical interlocking and clear position indication.

Engineering Support

Selection, GA drawing, SLD review and project submittals.

OEM Support

Project branding, secondary control and documentation options.

Reduced Site Work

Factory configuration and testing support smoother installation and commissioning.

Technical Parameters

ItemQCL-24 Series
Rated voltage24 kV
Rated frequency50 Hz
Rated current630 A
Switch-fuse combination rated currentUp to 125 A, fuse selection required
Rated short-time withstand current20 / 25 kA, 3 s
Rated peak withstand current50 / 63 kA
Power-frequency withstand voltage, 1 min65 kV
Lightning impulse withstand voltage125 kV
Gas tank protection degreeIP67
Final configurationAccording to approved SLD and technical specification

Functional Units & Configuration

UnitFunctionTypical Use
CLoad-break switch cable unitRing incoming/outgoing feeder
FSwitch-fuse combination unitTransformer protection
VVacuum circuit-breaker unitRelay-protected feeder
PTVoltage transformer unitMeasurement and auxiliary supply
MMetering unitProject metering

Applications

Utility Distribution
EPC & Substation
Industrial Power
Solar & BESS
Infrastructure
Mining

Product Details

Front Interface

Mimic diagram, mechanism, indication and secondary controls arranged for clear operation.

Primary System

Switching components and busbar are integrated within the gas-insulated enclosure.

Cable Compartment

Cable termination and accessory interfaces are selected for the confirmed project configuration.

GA Drawing & Dimensions

Complete GA drawings and cabinet arrangements are issued after SLD and configuration review. Dimensions remain subject to the approved project drawing.

Send Your SLD for GA Drawing →

Typical SLD

Typical C, F, V, PT and metering arrangements support ring-network, radial-feeder and transformer-protection schemes. Final SLD is confirmed during engineering review.

Manufacturing & Quality

Enclosure and gas-tank inspection
Busbar and mechanical assembly
Secondary wiring and component installation
Interlocking and operating tests
Electrical testing and FAT
Export packing and shipment checks

View Manufacturing & Quality →

Project, FAT & Shipment Evidence

Project evidence is organized by voltage, application, equipment scope, inspection, packing and shipment. Confidential customer names are not disclosed.

View Project Delivery Support →

Downloads

QCL-24 Public Datasheet

Corrected public document: 24 kV, 630 A, 20/25 kA for 3 s.

Download PDF

Project Documents

GA drawings, SLD and test-document scope are supplied against the confirmed configuration.

Request Controlled Documents →

FAQ

Can QCL-24 be used for 20kV and 22kV systems?

Project application is evaluated against system voltage, insulation level, frequency, short-circuit duty and local requirements.

What is required for selection?

SLD, rated voltage, current, short-circuit level, frequency, quantity, protection and communication requirements.

Is FAT available?

Inspection and FAT scope can be included in the agreed project document schedule.

Have a 20/22/24kV Project?

Send your voltage, quantity, SLD or technical specification for engineering review.

Request QuotationSend SpecificationWhatsApp Engineer

Additional Selection FAQ

Can QCL-24 be used for 20kV and 22kV systems?

Yes. A 24kV equipment class can serve 20kV and 22kV networks when the insulation level and project specification are satisfied.

How is the feeder combination selected?

Incoming, outgoing, transformer protection, bus section, metering and PT functions are arranged according to the approved SLD.

Are dimensions fixed?

Dimensions depend on the functional unit, cable interface and auxiliary requirements; final values are issued in the approved GA drawing.

Can FAT be witnessed?

Yes. Witness points and the FAT document scope can be agreed before production.

Model Meaning

QCL identifies the Qiangchi gas-insulated product family; 24 identifies the 24kV equipment class. The final feeder sequence and functional units are defined by the approved SLD.

QCL-24 can be evaluated for 20kV, 22kV and 24kV projects subject to the complete system specification. Short-time withstand duration is confirmed as 3 seconds for the applicable design.

Service Conditions & Project Confirmation

Ambient temperatureSubject to project specification and technical confirmation
AltitudeState the installation altitude in the RFQ; derating or design review may be required
Relative humidityConfirm maximum and average project conditions
Pollution and corrosionState pollution level, salt mist, dust and corrosive atmosphere where applicable
Seismic conditionProject-specific requirement to be confirmed
InstallationIndoor or outdoor enclosure, cable entry, room dimensions and service aisle must be specified

Standards and Technical Compliance

The applicable IEC standards, utility requirements, project specifications, inspection plan and document list are confirmed during technical clarification. Compliance statements apply only to the final approved configuration; no unverified certificate or test claim is implied.

Engineering, Packing & Shipment

After drawing approval, Qiangchi coordinates production, inspection, routine testing and the agreed FAT scope. Finished equipment is protected for handling and export shipment according to cabinet size, destination, transport method and contractual packing requirements.

Related Technical Guides

Review the Product Finder, Product Comparison and Selection Guides.

Request Project Configuration

Send the SLD, BOQ, specification, voltage, current, fault level, quantity and destination.

Upload SLD / Request Proposal   WhatsApp Engineer

Reviewed by Qiangchi Engineering Team · Updated September 12, 2026

Engineering Answers for QCL-24 Gas-Insulated Switchgear

What is this product?

QCL-24 Gas-Insulated Switchgear is a Qiangchi medium-voltage product configured for project-specific distribution requirements.

Which voltage levels are available?

24 kV class; applied to 13.8/20/22/24 kV systems subject to insulation coordination and the approved specification.

Where is it used?

It is used in medium-voltage distribution where compact construction and project-specific functional units are required.

How to select the configuration?

Selection follows the system voltage, rated current, short-circuit level, functional units, protection concept, cable interface, installation conditions and approved SLD.

Which standards and tests apply?

Applicable standards, routine tests and document scope are confirmed in the approved technical specification.

What information is required for quotation?

Send the SLD, system voltage, frequency, rated current, short-circuit level, quantity, project stage, required documents and delivery requirements.