QCL-12 12 kV gas-insulated ring main unit switchgear

QCL-12 Gas-Insulated Ring Main Unit

QCL-12 SERIES
12kV SF6 Gas-Insulated Ring Main Unit

Compact medium-voltage distribution equipment for utility networks, EPC substations, industrial power systems, solar plants, BESS and infrastructure projects.

12 kVRated Voltage
Up to 630 ARated Current
20/25 kA, 4 sShort-Time Withstand
50 HzFrequency
Request Technical ProposalSend Your SLDWhatsApp Engineer

Product Overview

QCL-12 is a metal-enclosed SF6 gas-insulated ring main unit designed for switching, protection and distribution in 12kV systems. The sealed primary circuit supports compact installation and stable service in space-limited substations. Functional units and secondary control are configured against the approved SLD and technical specification.

Core Advantages

Compact Design

Reduced equipment footprint for indoor substations and distribution rooms.

Flexible Configuration

C, F, V, PT and metering functions can be combined to match the project SLD.

Reliable Primary System

Sealed gas tank and controlled interlocking support safe, stable operation.

Project Customization

Protection, indication, metering, communication and cable interfaces are coordinated by project.

Drawing Support

GA drawings, SLD review and project submittals are available before production.

Export Support

FAT, documentation and export packing are coordinated for international delivery.

Technical Parameters

ItemQCL-12 Series
Rated voltage12 kV
Rated frequency50 Hz
Rated currentUp to 630 A, subject to functional unit
Rated short-time withstand current20 / 25 kA, 4 s
Rated peak withstand current50 / 63 kA
Power-frequency withstand voltage, 1 min42 kV
Lightning impulse withstand voltage75 kV
Gas tank protection degreeIP67
Final configurationAccording to approved SLD and technical specification

Functional Units & Configuration

UnitFunctionTypical Project Use
CLoad-break switch cable unitRing incoming/outgoing feeder
FSwitch-fuse combination unitTransformer protection
VVacuum circuit-breaker unitFeeder or transformer protection with relay
PTVoltage transformer unitVoltage measurement and auxiliary supply
MMetering unitProject metering configuration

Applications

Utility Distribution
EPC & Substation
Industrial Power
Solar & BESS
Infrastructure
Mining

Product Details

Front & Operating Interface

Mimic diagram, mechanical position indication and operating points arranged for clear operation.

Sealed Primary Compartment

Busbar and switching components are integrated in the gas-insulated primary enclosure.

Cable & Secondary Compartments

Cable connection, protection, control and communication interfaces are configured to the project.

GA Drawing & Dimensions

Cabinet arrangement and overall dimensions are issued with the approved project drawing. Full GA drawings are supplied without cropping after configuration confirmation.

Send Your SLD for GA Drawing โ†’

Typical SLD

Typical C, F, V, PT and metering arrangements can be combined for single-bus, ring-network and transformer-feeder schemes. The final SLD is subject to engineering review.

Manufacturing & Quality

Enclosure and gas-tank inspection
Busbar and mechanical assembly
Secondary wiring and component installation
Interlocking and operating tests
Electrical testing and FAT
Finished-product inspection and export packing

View Manufacturing & Quality โ†’

Project, FAT & Shipment Evidence

Project records are organized by application, voltage, equipment scope, FAT, packing and shipment. Customer names are omitted where confidentiality applies.

View Project Delivery Support โ†’

Downloads

QCL-12 Product Catalogue

Verified public product-family catalogue.

Download PDF

Project Documents

GA drawings, SLD and test-document scope are supplied against the confirmed configuration.

Request Controlled Documents โ†’

FAQ

What information is required for selection?

Rated voltage, rated current, short-circuit level, frequency, quantity, functional units, SLD, protection requirements and site conditions.

Can the configuration be customized?

Yes. Functional units, protection, metering, communication, cable interfaces and documentation are coordinated against the approved specification.

Is FAT available?

Inspection and FAT scope can be agreed as part of the project document schedule.

Have a 12kV MV Project?

Send your voltage, quantity, SLD or technical specification for engineering review.

Request QuotationSend SpecificationWhatsApp Engineer

Additional Selection FAQ

What does 630A 25kA mean?

630A is the normal-current rating and 25kA is the short-circuit withstand level. The required duration and final rating follow the network study and specification.

How is the C/V/F combination selected?

C is commonly used for cable switching, V for circuit-breaker protection and F for switch-fuse transformer protection. The final combination follows the SLD.

Can GA drawings be provided before production?

Yes. Project-specific GA drawings and interface details are prepared after technical clarification.

What happens during FAT?

The agreed FAT scope can include mechanical operation, interlocking, wiring, protection checks and routine electrical tests.

Model Meaning

QCL identifies the Qiangchi compact gas-insulated product family; 12 identifies the 12kV equipment class. Functional-unit letters and feeder combinations are confirmed from the project SLD.

For 10kV and 11kV distribution projects, the final 12kV equipment selection is confirmed against the specification and insulation requirements.

Service Conditions & Project Confirmation

Ambient temperatureSubject to project specification and technical confirmation
AltitudeState the installation altitude in the RFQ; derating or design review may be required
Relative humidityConfirm maximum and average project conditions
Pollution and corrosionState pollution level, salt mist, dust and corrosive atmosphere where applicable
Seismic conditionProject-specific requirement to be confirmed
InstallationIndoor or outdoor enclosure, cable entry, room dimensions and service aisle must be specified

Standards and Technical Compliance

The applicable IEC standards, utility requirements, project specifications, inspection plan and document list are confirmed during technical clarification. Compliance statements apply only to the final approved configuration; no unverified certificate or test claim is implied.

Engineering, Packing & Shipment

After drawing approval, Qiangchi coordinates production, inspection, routine testing and the agreed FAT scope. Finished equipment is protected for handling and export shipment according to cabinet size, destination, transport method and contractual packing requirements.

Related Technical Guides

Review the Product Finder, Product Comparison and Selection Guides.

Request Project Configuration

Send the SLD, BOQ, specification, voltage, current, fault level, quantity and destination.

Upload SLD / Request Proposal   WhatsApp Engineer

Verified evidence

Model-Specific 2026 Type Test Reports

Original type-test reports have been checked for the QCL (STQCL)-12 C, F and V functional units. Public display is limited to report covers and controlled metadata; full report interiors are supplied only for technical and project review.

  • 2026XHT06258: QCL (STQCL)-12-C/630-25 โ€” 12 kV, 630 A, 25 kA
  • 2026XHT06259: QCL (STQCL)-12-F/125-31.5 โ€” 12 kV, 125 A, 31.5 kA
  • 2026XHT06260: QCL (STQCL)-12-V/630-25 โ€” 12 kV, 630 A, 25 kA

Test standards: GB/T 11022-2020 and GB/T 3906-2020. Applicability is limited to the stated model and report scope.

View Report CoversRequest Full ReportWhatsApp Engineering

Reviewed by Qiangchi Engineering Team ยท Updated September 13, 2026

Engineering Answers for QCL-12 Gas-Insulated Ring Main Unit

What is this product?

QCL-12 Gas-Insulated Ring Main Unit is a Qiangchi medium-voltage product configured for project-specific distribution requirements.

Which voltage levels are available?

12 kV class; applied to 10/11/12 kV distribution projects subject to the approved specification.

Where is it used?

It is used in compact utility, commercial and industrial distribution networks.

How to select the configuration?

Selection follows the system voltage, rated current, short-circuit level, functional units, protection concept, cable interface, installation conditions and approved SLD.

Which standards and tests apply?

Verified type-test evidence includes reports 2026XHT06258, 2026XHT06259 and 2026XHT06260; scope follows each original report.

What information is required for quotation?

Send the SLD, system voltage, frequency, rated current, short-circuit level, quantity, project stage, required documents and delivery requirements.