Air-insulated metal-enclosed switchgear

12 kV air-insulated ring main unit

An air-insulated, metal-enclosed cabinet family for 11/12 kV distribution projects. Match the switching devices, protection and panel arrangement to your network and installation requirements.

12 kVEquipment class
630 ACurrent reference
AirCabinet insulation

No drawing yet? Start with your country, application and a short description.

XGN15-12 product arrangement reference
Typical XGN15-12 air-insulated panel arrangement. Final line-up follows the approved SLD and drawings.

XGN15-12 / Product overview

Make the cabinet and switching-device choices explicit

Cabinet insulation and the medium inside a switching device are separate specification decisions.

01

Air-insulated cabinet

XGN15-12 is an air-insulated, metal-enclosed product family. State the required installation arrangement and service conditions.

02

Selected switching devices

Load switches, fuse combinations and circuit breakers are selected for the feeder duty. Confirm each installed device and its insulating or interrupting medium.

03

Coordinated installation

Review cable entry, operating access, room or enclosure dimensions, interlocks and secondary equipment against the selected panel layout.

Technical reference

Key specifications and their application

Use the reference values below to start selection. The confirmed unit, drawings and technical agreement define the supplied equipment.

On a small screen, scroll the table horizontally to see the scope of each value.

XGN15-12 technical reference and scope
ItemReferenceHow to apply it
Product familyXGN15-12Air-insulated, metal-enclosed cabinet
Rated voltage class12 kV11 kV network use subject to insulation coordination and utility requirements
Rated current reference630 AConfirm the selected circuit and approved rating schedule
FrequencyConfirm from the selected datasheetState the project frequency in the RFQ
Short-time withstand dutyProject-specificConfirm current and duration for the selected panel
Functional panelsLoad-break switch / fused switch / VCB / metering / PTFinal selection follows the project SLD
Switching-device mediumConfirm for each selected deviceDistinct from the air-insulated cabinet classification
Dimensions and cable interfacesSelected arrangement drawingConfirm installation envelope and service access

Configuration & interfaces

Build the line-up around the feeder functions

Select the required panel function, then coordinate the installed devices and secondary circuits.

LBS

Load-break switching

Incoming, outgoing and ring-main switching functions, with the chosen operating mechanism and earthing arrangement.

F

Fused transformer feeder

Switch-fuse arrangement coordinated with transformer characteristics and the protection scheme.

VCB

Circuit-breaker feeder

Circuit-breaker protection and control, coordinated with relays, CT/VT requirements and auxiliary supply.

Technical documents

Find the document for your next decision

Use product information for initial selection, then confirm project drawings and the evidence for the exact equipment you specify.

Engineering documents

Controlled technical datasheet

Configuration request

Request the ratings and device schedule for the exact XGN15-12 line-up you need.

Request the datasheet

Engineering documents

Drawings & technical submittals

Project documents

Coordinate the SLD, arrangement, cable interfaces and agreed document list.

Explore technical submittals

Engineering documents

Air-insulated or gas-insulated?

Selection guide

Understand the product-family distinction before choosing equipment for your project.

Read the selection guide

Working with Qiangchi

A clear path from requirements to agreed supply

For EPCs, panel builders, contractors and local partners, start with the equipment schedule and the responsibilities for the project.

  1. Share the SLD / BOQ

    Send your equipment requirements, destination and available specification.

  2. Review the configuration

    Clarify equipment scope, interfaces and applicable technical documents.

  3. Receive the proposal

    Review the project-specific technical proposal and quotation.

  4. Agree the supply

    Confirm the drawings, equipment, inspection documents and commercial scope.

The local partner handles local engineering and market-access requirements. Qiangchi supplies the equipment and documentation agreed for the order.

Selection questions

XGN15-12 questions

What is the XGN15-12?

It is a 12kV-class air-insulated ring main unit used for switching, protection and distribution in 11/12kV networks.

Can XGN15-12 be used on an 11kV system?

Yes. An 11kV network commonly uses equipment from the 12kV rated-voltage class, subject to the project insulation level and utility specification.

Which functional units are available?

Typical arrangements include load-break switch, fuse-switch, circuit-breaker, metering and PT units. Final availability follows the approved SLD.

What does 630A mean?

630A is the normal-current rating for the main circuit. Cable, busbar and feeder selection must also satisfy the project load and temperature-rise requirements.

What information is required?

Voltage, current, fault level, frequency, quantity, SLD, BOQ, cable details and technical specification.

Are dimensions fixed?

Panel dimensions and lineup length depend on the functional units, mechanism, cable entry and auxiliary equipment. Final dimensions are issued in the approved GA drawing.

Can FAT be arranged?

Yes. Routine tests, witness points and project document requirements can be agreed before production.

Can Qiangchi support OEM or EPC projects?

Yes. Project-specific configuration, drawings, component coordination and technical submittal support are available against confirmed requirements.

Prepare your enquiry

Bring the details you already have

You do not need a complete tender package to start. These details help move the enquiry towards a configuration and quotation.

  • Country and system voltage
  • SLD, panel functions and quantity
  • Current, fault duty and frequency
  • Switch devices, protection and auxiliary supply
  • Cable entry, site conditions and available space
  • Required documents and delivery schedule

Discuss your XGN15-12 requirement